Error Codes

Adams Solver issues "Simulate status" or "Termination status" codes when a simulation ends, along with a verbose error message description. The following table details the meanings of the numeric codes issued by Solver:
 
Parameter
Value
Description
NOERRS
0
No errors
INPERR
-101
Errors while opening Adams output files
BADSIT
-102
Site security checking not successful
ERINPT
-105
Errors while reading in Adams dataset
ERVRFY
-117
Model did not pass verification phase
ERMEMO
-118
Problem during memory initialization phase
ERRVRS
-119
UCONFG Version mismatch
ERRDIM
-120
UCONFG passes negative array dimensions
ERRLCK
-121
Lockup detected
BADMEM
-122
Problem allocating memory
BADAMD
-123
Problem initiating AMD Command Parser
ERRSML
-124
Simulation failure detected
NOTCXX
-125
The Model is not compatible with the Adams Solver (C++)
TRMRCR
-993
Recursion encountered when trying to terminate
SNHALT
-994
Sensor Halt was imposed
ERTERM
-995
Abnormal termination of Solver
PRFLER
-996
Program Fault was encountered
INPTRM
-997
Session terminated before completion during input phase
TERMNT
-998
Current session terminated before completion
The above termination codes can be displayed by using the PREFERENCES/STATUS_MESSAGE=ON solver command. See the PREFERENCES solver command (Adams Solver C++ only).