clearance compute

Allows you to carry out the specified clearance study for post-processing clearances. Use the menu items Tools Clearance Compute in Adams PostProcessor, to execute a clearance study.

Format:

 
clearance compute
analysis_name =
existing analysis
treat_flex_as_rigid =
yes/no

Example:

 
clearance compute &
analysis_name =
Last_Run &
treat_flex_as_rigid =
yes

Description:

 
Parameter
Value Type
Description
analysis_name
Existing Analysis
This parameter gets assigned the name of an existing simulation analysis.
treat_flex_as_rigid
Boolean
Decides if the flexible bodies should be treated as rigid bodies while executing the clearance study.

Extended Definition:

The clearance study which is being carried out uses the analysis specified by the existing_analysis parameter as the basis of the study.
 
Note:  
This command is for computing post-processing clearances only. Run-time clearances will not be computed using this command.
 
Caution:  
Clearance Studies are not designed to handle cases where one geometry (I or J) is completely enclosed by the other. Unexpected results can occur.