clearance compute | |
|---|---|
analysis_name = | existing analysis |
treat_flex_as_rigid = | yes/no |
clearance compute & | |
|---|---|
analysis_name = | Last_Run & |
treat_flex_as_rigid = | yes |
Parameter | Value Type | Description |
|---|---|---|
analysis_name | Existing Analysis | This parameter gets assigned the name of an existing simulation analysis. |
treat_flex_as_rigid | Boolean | Decides if the flexible bodies should be treated as rigid bodies while executing the clearance study. |
Note: | This command is for computing post-processing clearances only. Run-time clearances will not be computed using this command. |
Caution: | Clearance Studies are not designed to handle cases where one geometry (I or J) is completely enclosed by the other. Unexpected results can occur. |