Adams Car Package > Shared Material > Dialog Box - F1 Help > Eigen Solution Calculation

Eigen Solution Calculation

(Standard Interface) Simulate DOE Interface Simulation Script New Script Type: Adams Solver Commands            Shared Dialog Box
Simulation Create a new Simulation Script Script Type: Adams Solver Commands
Specifies options for creating ACF command for Eigen Solution Calculation.
 
For the option:
Value Type
Do the following:
Include Damping
Yes/No
Option to include damping.
Plant State Name
Existing plant state name
Name of the Plant State already existing in the model to be used for Eigen analysis.
Reference Marker
Existing marker
Reference marker for Eigen analysis. Based on the settings, the relative coordinates are created.

Without RM all default linearization coordinates are global. Using RM all default coordinates are relative to the RM marker.

The RM option is useful in linearizing helicopter blades, turbines and so on. If no RM option is used, the computed frequencies reflect a dependency on the rotation frequency, hiding the frequencies of interest. When the RM option is used, Adams Solver (C++) selects a subset x of the coordinates shown in the table above to perform the linearization.

For more details see section Using the RM option.
Compute Eigenvalues and Eigenvectors / compute Eigenvalues only
string
Specify if only eigenvalues are to be calculated or of both eigenvalues and eigenvectors should be calculated.
Frequency Range /Mode Range
string
Specify if results should be output for only a subset of the system modes. Define the subset either as the set of modes which lie within a given frequency range (frequency range) or as a range of specific mode numbers (mode range).
Energy Of Modes
Integer
Range i1[,i2] of mode energy distribution. If you do not specify the number of modes you want to compute, Adams Vibration automatically chooses a suitable number of modes based on the model size. This options shows only if F77 solver is selected.
Range: i2 > i1 > 0
Coordinates Of Modes
Real/Integer
Range i1[,i2] of coordinates for modes/frequencies.
Range:
i2 > i1 > 0 when Mode Range is selected.
r2 > r1 > 0.0 when Frequency Range is selected.
Dissipative Energy
Real/Integer
Range i1[,i2] of dissipative energy distribution for modes/frequencies.
Range:
i2 > i1 > 0 when Mode Range is selected.
r2 > r1 > 0.0 when Frequency Range is selected.
Kinetic Energy
Real/Integer
Range i1[,i2] of kinetic energy distribution for modes/frequencies.
Range:
i2 > i1 > 0 when Mode Range is selected.
r2 > r1 > 0.0 when Frequency Range is selected.
Strain Energy
Real/Integer
Range i1[,i2] of strain energy distribution for modes/frequencies.
Range:
i2 > i1 > 0 when Mode Range is selected.
r2 > r1 > 0.0 when Frequency Range is selected.
Names
Yes/No
If selected, this will list the energy contribution results by Adams View object name instead of Adams Solver ID. This options shows only if C++ solver is selected.
Table Precision
Integer
Specify the number of decimal places to be used in the energy table output. This options shows only if C++ solver is selected.