For the option: | Do the following: |
|---|---|
Tips on Entering Object Names in Text Boxes. | |
Condition Sensor | If creating a condition sensor, enter a name for it. If modifying a condition sensor, enter its database name. |
Variable | Enter a database object of type data_element variable or measure solver computed. |
Label | Enter a label string for the condition sensor. This label string will be used in event files (.xml) to select a condition sensor for end conditions. Learn about Working with Event Files (.xml). |
Units | Select units for the condition sensor. The standard driver interface (SDI) uses this information to convert the trigger values and error tolerances between different unit systems. If you select no_units, Adams Car does not perform a conversion. |
Scale Factor | Enter a scalar real number, which is multiplied to the variable object function by the SDI. This scale factor is mutually exclusive with predefined unit types, and can be used to used to enter trigger values and error tolerances in a different units system than that being used in the model (and therefore calculated by the variable object). |
![]() | Select to display a dialog box where you can add multi-line comments to any entity, to describe its purpose and function. Your template-based product displays different comments dialog boxes, depending on the entity type for which you want to record comments: ■If recording comments for modeling entities in Standard Interface, your template-based product displays the Entity Comments dialog box. ■If recording comments for any other entity type, your template-based product displays the Modify Comment dialog box. Learn about Recording Comments. |